- High accuracy
- Wide flow range
- Fast response to rate changes
- Simplicity of construction with few parts
- Cost effective
- Calibration traceable to NIST
Gas
from 28 up to 7000 l/min
from 267 up to 230 °C
from 0 up to 400 bar
General industry, Chemical industry, Oil industry, Gas industry
General information
A series of flow meters designed for precise flow rate measurement of all compressible fluids with a minimum pressure loss. Accuracies of ±0.5% are available depending on fluid conditions, consult factory for data. The series comprises three basic designs. For low, medium, and high density gases. This variety of design permits accurate flow measurement under operating densities from 0,16 to 240 kg/m3 (at flow ranges from 0,1 to 180 l/s). Virtually any type of clean gas can be measured - argon, air, helium, oxygen, ammonia, methane, nitrogen, etc. Repeatability is ±0.25% of reading. Response, despite the low densities, is a reasonable 10 to 20 milliseconds.
Technical data
Flow range | Up to 1000 SCFM |
Size | 1/2" up to 2" |
Accuracy | ±2 % of actual value |
Repeatability | ±0,25 % of actual value |
Pressure* | 410 bar (NPT) |
Housing | 316 SST |
*depending on end connections |
Downloads
Measuring principle
Turbine meters Cox|Blancett

Turbine meters are volumetric meters. When the fluid passes through, a rotor is activated and the movement is either electronically or mechanically transmitted outside.
Applications
Turbine meters are only for applications with low viscosity fluids and gases.

Highly-precise turbine meter series for high requirements
Accessories
- Multiple isolated outputs
- 10 selectable fluid tables
- Precision temperature compensation methods
- Service/test mode
- Batch...
- Monitors up to three independent flow sensors
- Automatic switching for manifold applications
- Unique remote control or...
- ATEX, IECEx, FM and CSA approved
- Integrated data logger
- ModBus® RS485 communication option
Do you have questions on this product?
Your contact person: