Ultrasonic flow meter Multysonic 8000

for open channels, semi- or fullfilled pipes

Ultrasonic flow meter Multysonic 8000

Maintainance-free
Recording backflow & back up
No culverts required
Ex-approved
High accuracy
For channels from 0,2 to 50 m wide
For different channel profiles
Easy software updates via USB
Remote control via internet

The ultrasonic flow meter MultySonic 8000 has been especially designed for flow measurement of fluids in  pipes (semi- or fullfilled pipes), rivers and streams with a width of 0.2m – 50m. Measurements can take place  in pressure pipes up to 100 bars and under highly variable levels. A variety of sensor forms and materials  permit use under heavy mechanical load and in aggressive media with pH values from 3.5 to 10.

Measurement principle
Measurement of the flow speed is carried out at several levels according to the ultrasonic transit time method
principle in combination with the pulse modulated Doppler process. A big advantage of the transit time method is the absolute determination of the mean flow rate between two
fixed sensors. This makes complicated and questionable calibrations unnecessary.

Applications
Serwage plants

  • Monitoring of sewage plants inflow and outflow according to the German self-monitoring regulation (EkVO)
  • Control of rain trapping ponds
  • Feeding of parallel ponds
  • Monitoring the after-purification

Drain water associations and city works

  • Recording the exact discharge quantities
  • Recognition of false water quantities
  • Checking and acquisition of the canal hydrology
  • Recording velocity profiles


Thermal power stations
Here, MultySonic 8000 reliably carries out

  • The monitoring of tapped and recycled cooling water
    quantities for accounting purposes
  • Energy balancing to avoid impermissible flow heating
  • Exact determination of the mean water temperature, even in case of temperature skeins
  • Optimization of the pump performance

Special advantages
IDM accuracies in pressure pipes with little construction effort. Reliable quantity acquisition in the inflow of river power stations, turbine acceptance measurements.
Exact, mean temperature measurement of the medium.     
Installing and dismantling possilbe under operating conditions.
Exact calculation of discharge costs with government agencies.


UF Multy8000 Installation manual
 UF_Multy8000_IA_02_0672.pdf
UF Multy8000 User manual
 UF_Multy8000_BA_02_0441.pdf
UF Multy8000 Data sheet
 UF_Multy8000_DB_02_0443.pdf
UF Multy8000 Data sheet_sp
 UF_Multy8000_DB_04_0765.pdf
UF Multy8000 Overview
 UF_Multy8000_UB_02_0023.pdf

Sample applications

Influent flow measurement from a channel network to a water treatment plant

Influent flow measurement from a channel network to a water treatment plant

Translation in process

more Information

Flow measurement in natural flowing waters

Flow measurement in natural flowing waters

Basic principlesDepending on flow or outflow, characteristics of flowing waters...

more Information

Flow measurement in channels with complex geometry

Flow measurement in channels with complex geometry

Translation in process

more Information

Flow measurement in stormwater overflow basins

Flow measurement in stormwater overflow basins

Translation in process

more Information

Messung eines Fließabschnittes

Messung eines Fließabschnittes

Lässt sich in einem Fließabschnitt (Gewässer oder Kanal) ein kontinuierliches...

more Information

Forgot your password?